Breakdown Causes | Solutions |
DA98 driver is used in system, system gives drive alarm due to drive failure and at the same time the drivers gives alarm too | Read the operating instruction of DA98 driver or the appendix of this manual, find out breakdown causes based on driver alarm code, then handle the breakdown according to instructions |
Step driver is used in system. system gives drive alarm due to drive failure | Check if the red alarm light is on. If so, check if the power supply circuit is broken; check if there is water damage in the driver. If so, dry the driver and install protective device; if it still doesn’t work, then send the driver to the manufacturer for maintenance |
Tight mechanical screw causes mechanical stuck, motor overload and overheat, triggering driver alarm | As for mechanical tightness, adjust the screw or other mechanical parts; as for overload, then check the cutting output and feeding speed, improve the technique or change motor or driver with larger load |
Water and oil damage in motor plug and socket burns down the interface; motor insulation damage leads to the short circuit of power amplifier tube and driver alarm; motor damage causes driver alarm | If there is water in the socket interface, change plug or socket and take waterproof and insulation measures; if there is breakdown of diver power amplifier tube, change the driver power amplifier tube 460 and a motor with better insulativity; check the motor. Disconnect the motor and the driver, run the driver without the motor, modify the selection of motor high and low level. If no alarm sent, then it is motor damage or motor shortage |
Mismatch between driver and motor, use the driver with large current to drive the motor with low current | Change driver or motor and make them match. Servo drive must be matched with servo motor |
Inoperation of the driver leads to system alarm | Check the driver power circuit, check if there is broken circuit or damaged components which causes no power supply for the driver; check if the motor is short circuited, causing damage to the driver fuse or power amplifier tube and no power supply for the driver; if the power circuit fails, then send the driver to the manufacturer for maintenance |